Product Details
Digital Pressure Sensor orginal germany
The Cerabar PMC51 digital pressure transmitter with capacitive, oil-free ceramic measuring cell is typically used in process and hygienic applications for pressure, level, volume or mass measurement in liquids and gases. It guarantees high degree of system safety thanks to vacuum-proof ceramic membrane with integrated breakage detection. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2 according to IEC 61508 / IEC 61511.
specifications
-
Measuring principle
Absolute and gauge pressure
-
Characteristic / Application
Smart and reliable pressure transmitter, with capacitive measuring cell and ceramic process isolating diaphragm (Ceraphire)
-
Supply / Communication
4 ..20mA HART: 11,5...45V DC Ex ia: 11,5...30V DC PROFIBUS PA FOUNDATION Fieldbus
-
Accuracy
0,15% Platinum 0,075%
-
Long term stability
< 0,1% of URL/ year < 0,25% of URL/ 5 years < 0,4% of URL/ 10 years
-
Ambient temperature
-40°C...85°C (-40°F...185°F)
-
Process temperature
-20°C...125°C (-4°F...275°F)
-
Process pressure absolute / max. overpressure limit
60bar (900psi)
-
Pressure measuring range
100mbar...40bar (1.5psi...600psi)
-
Main wetted parts
Ceraphire Sealing Alloy C276 316L
-
Process connection
Threads Flanges (DIN, ASME, JIS)
-
Max. measurement distance
400m (1312ft) H2O
-
Communication
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus
-
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI
-
Safety approvals
SIL
-
Design approvals
EN 10204-3.1 NACE MR0175, MR0103
-
Hygienic approvals
3A, EHEDG CoC ASME-BPE
-
Marine approval
GL/ ABS/ LR/ BV/ DNV
-
Drinking water approvals
NSF
-
Options
local display
-
Application limits
Measuring cell: ceramics If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure